Logo image
Estimating axonal strain and failure following white matter stretch using contactin-associated protein as a fiduciary marker
Journal article   Peer reviewed

Estimating axonal strain and failure following white matter stretch using contactin-associated protein as a fiduciary marker

Sagar Singh, Assimina A. Pelegri and David I. Shreiber
Journal of biomechanics, Vol.51, pp.32-41
01/25/2017
PMID: 27939751

Abstract

Engineering, Biomedical Life Sciences & Biomedicine Science & Technology Biophysics Engineering Technology
Axonal injury occurs during trauma when tissue-scale loads are transferred to individual axons. Computational models are used to understand this transfer and predict the circumstances that cause injury. However, these findings are limited by a lack of validating experimental work examining the mechanics of axons in their in situ state. As a first step towards validation for dynamic stretch, we use contactin-associated protein (Caspr), expressed at the nodes of Ranvier, as a fiduciary marker of quasistatic axonal stretch. We measured changes in the distance between immunolabled Caspr pairs along axons as a function of tissue-level stretch in chick embryo spinal cords harvested from different developmental periods. We then identified and characterized broken axons and adapted a kinematic model published previously by our group (Singh et al., 2015) to estimate average strain thresholds for axon mechanical failure. The distance between Caspr pairs increased with stretch, though not as much as predicted by simple continuum mechanics. For equivalent tissue stretch, greater numbers of broken axons were found at later stages of development. In adapting our kinematic model to predict a breaking threshold strain, we found that breaking thresholds decrease with development stage. When thresholds were split and classified based on kinematic behavior, non-affine, uncoupled axons had higher strain thresholds than affine, coupled axons, corroborating thresholds predicted from in vitro and in vivo preparations. These results provide a valuable launching point for generating more accurate multi-scale models in primary central nervous system injury.
pdf
Singh - JBiomech6.87 MB
Version of Record (VoR) Restricted Access, To request access, contact soarhelp@libraries.rutgers.edu.
url
https://doi.org/10.1016/j.jbiomech.2016.11.055View
Version of Record (VoR) Journal of biomechanics
url
Report an accessibility issueView
Please complete a content remediation request to report an accessibility issue with a library electronic resource, website, or service.

Metrics

Details

Logo image