Finite element modeling of CNS white matter kinematics: use of a 3D RVE to determine material properties
Journal article   Peer reviewed

Finite element modeling of CNS white matter kinematics: use of a 3D RVE to determine material properties

Yi Pan, Daniel Sullivan, David I. Shreiber and Assimina A. Pelegri
Frontiers in bioengineering and biotechnology, Vol.1, pp.19-19
12/09/2013
PMID: 25152875

Abstract

axonal injury Bioengineering and Biotechnology microstructural properties multi-scale modeling Spinal Cord Injury Traumatic Brain Injury
Axonal injury represents a critical target area for the prevention and treatment of traumatic brain and spinal cord injuries. Finite element (FE) models of the head and/or brain are often used to predict brain injury caused by external mechanical loadings, such as explosive waves and direct impact. The accuracy of these numerical models depends on correctly determining the material properties and on the precise depiction of the tissues’ microstructure (microscopic level). Moreover, since the axonal microstructure for specific regions of the brain white matter is locally oriented, the stress, and strain fields are highly anisotropic and axon orientation dependent. Additionally, mechanical strain has been identified as the proximal cause of axonal injury, which further demonstrates the importance of this multi-scale relationship. In this study, our previously developed FE and kinematic axonal models are coupled and applied to a pseudo 3-dimensional representative volume element of central nervous system white matter to investigate the multi-scale mechanical behavior. An inverse FE procedure was developed to identify material parameters of spinal cord white matter by combining the results of uniaxial testing with FE modeling. A satisfactory balance between simulation and experiment was achieved via optimization by minimizing the squared error between the simulated and experimental force-stretch curve. The combination of experimental testing and FE analysis provides a useful analysis tool for soft biological tissues in general, and specifically enables evaluations of the axonal response to tissue-level loading and subsequent predictions of axonal damage.
pdf
FrontiersinBiomech3.97 MB
Version of Record (VoR) Restricted Access, To request access, contact soarhelp@libraries.rutgers.edu. CC BY V4.0
url
https://doi.org/10.3389/fbioe.2013.00019View
Version of Record (VoR) Open
url
Report an accessibility issueView
Please complete a content remediation request to report an accessibility issue with a library electronic resource, website, or service.

Metrics

20 Record Views